On the use of a consumer-grade 360-deg camera as a radiometer for scientific applications
Version 3 2024-09-04, 16:42Version 3 2024-09-04, 16:42
Version 2 2024-09-04, 15:03Version 2 2024-09-04, 15:03
Version 1 2024-09-04, 15:02Version 1 2024-09-04, 15:02
Posted on 2024-09-04 - 16:42
Improved miniaturization capabilities for complex fisheye camera systems have recently led to the introduction of many compact 360-degree cameras on the consumer technology market. Designed primarily for recreative photography, several manufacturers have decided to allow users access to raw imagery for further editing flexibility, thereby offering data at sensor level that can be directly exploited for absolute-light quantification. In this study, we demonstrate methodologies to carefully calibrate a consumer-grade 360-degree camera for radiometry use. The methods include geometric calibration, assessment of the illumination fall-off across the image plane, spectral-response determination, absolute spectral-radiance calibration, linearity, and dark-frame analysis. Accuracy of the calibration was evaluated by comparing sky radiance measurements with a co-localized Compact Optical Profiling System (C-OPS, Biospherical Instruments Inc.), which gave mean unbiased percentage differences of less than 21.1 %. Using the photon-transfer technique, we calculated that this camera consisting of two fisheyes with a 182˚ field of view in air (152˚ in water) has a limit of detection of at least 4.6 x 10⁻⁷ W∙sr⁻¹∙m⁻²∙nm⁻¹ in its three spectral channels. This technology, with properly stored calibration data, may benefit researchers from multiple scientific areas interested in radiometric geometric light-field study. While some of these radiometric calibration methods are complex or costly, this work opens up possibilities for easy-to-use, inexpensive, and accessible radiance cameras.
CITE THIS COLLECTION
DataCite
DataCiteDataCite
3 Biotech3 Biotech
3D Printing in Medicine3D Printing in Medicine
3D Research3D Research
3D-Printed Materials and Systems3D-Printed Materials and Systems
4OR4OR
AAPG BulletinAAPG Bulletin
AAPS OpenAAPS Open
AAPS PharmSciTechAAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität HamburgAbhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)ABI Technik (German)
Academic MedicineAcademic Medicine
Academic PediatricsAcademic Pediatrics
Academic PsychiatryAcademic Psychiatry
Academic QuestionsAcademic Questions
Academy of Management DiscoveriesAcademy of Management Discoveries
Academy of Management JournalAcademy of Management Journal
Academy of Management Learning and EducationAcademy of Management Learning and Education
Academy of Management PerspectivesAcademy of Management Perspectives
Academy of Management ProceedingsAcademy of Management Proceedings
Academy of Management ReviewAcademy of Management Review
Larouche, Raphael; Girard, Simon Lambert; Katlein, Christian; Marty, Sabine; Leymarie, Edouard; Thibault, Simon; et al. (2024). On the use of a consumer-grade 360-deg camera as a radiometer for scientific applications. Optica Publishing Group. Collection. https://doi.org/10.6084/m9.figshare.c.7127236.v3