Software configurable optical test system: a computerized reverse Hartmann test
Posted on 2017-04-21 - 12:58
A software configurable optical test system (SCOTS) based on the geometry of the fringe reflection or phase measuring deflectometry method was developed for rapidly, robustly, and accurately measuring large, highly aspherical shapes such as solar collectors and primary mirrors for astronomical telescopes. In addition to using phase shifting methods for data collection and reduction, we explore the test from the point view of performing traditional optical testing methods, such as Hartmann or Hartmann–Shack tests, in a reverse way. Using this concept, the slope data calculation and unwrapping in the test can also be done with centroiding and line-scanning methods. These concepts expand the test to work in more general situations where fringe illumination is not practical. Experimental results show that the test can be implemented without complex calibration for many applications by taking the geometric advantage of working near the center curvature of the test part. The results also show that the test has a large dynamic range, can achieve measurement accuracy comparable with interferometric methods, and can provide a good complement to interferometric tests in certain circumstances. A variation of this method is also useful for measuring refractive optics and optical systems. As such, SCOTS provides optical manufacturers with a new tool for performing quantitative full field system evaluation.
CITE THIS COLLECTION
DataCiteDataCite
3 Biotech3 Biotech
3D Printing in Medicine3D Printing in Medicine
3D Research3D Research
3D-Printed Materials and Systems3D-Printed Materials and Systems
4OR4OR
AAPG BulletinAAPG Bulletin
AAPS OpenAAPS Open
AAPS PharmSciTechAAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität HamburgAbhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)ABI Technik (German)
Academic MedicineAcademic Medicine
Academic PediatricsAcademic Pediatrics
Academic PsychiatryAcademic Psychiatry
Academic QuestionsAcademic Questions
Academy of Management DiscoveriesAcademy of Management Discoveries
Academy of Management JournalAcademy of Management Journal
Academy of Management Learning and EducationAcademy of Management Learning and Education
Academy of Management PerspectivesAcademy of Management Perspectives
Academy of Management ProceedingsAcademy of Management Proceedings
Academy of Management ReviewAcademy of Management Review
Su, Peng; Parks, Robert E.; Wang, Lirong; Angel, Roger P.; Burge, James H. (2010). Software configurable optical test system: a computerized reverse Hartmann test. Optica Publishing Group. Collection. https://doi.org/10.6084/m9.figshare.c.3748010.v1